- Better efficiency - On-demand power uses less fuel than other popular generator models both while running and at rest
- Dual Fuel - 2 types applicable in one unit: Gasoline or Propane
- Hassle-free electric start system with remote start lets you start the generator from inside the coach
- Designed for reliable service with all total low harmonic distortion for use with sensitive electronics.
- Emergency backup recoil start gives you further peace of mind when you are using the Flex Power 4000i – No other generator has this capability
- Multi-pole PM brushless alternator incorporates a digital voltage regulator. The total harmonic distortion is only 3%, which makes it safer to power all types of electronic devices.
- Offers stepped-up power-on-demand, eliminating issues of overload. The motor slows down when you reduce load and will speed up when you resume a higher load. High performance, low cost, quiet operations, and fuel efficiency make this RV generator the best in its class by every measure.
- Compared to the competition: The Flex Power™ 4000i is lighter, more fuel efficient, lower in harmonic distortion, quieter, has a higher base load, and has many more features.
- 100% replacement for Onan installed generators - Fits in the same space as Onan and other competitors.
- Your safety is our concern, the Flex Power™ 4000i includes many safety features that go above and beyond industry standards. Including a digital valve controller that offers auto shut-off for fire prevention.
- Consistent output - Less distortion (3% compared to 17% in competitive models) allows you to power sensitive devices like laptops, TVs, and gaming counsels, without worrying about overload
- Softer sound - Consistent output allows for a quieter run without loud rev cycles
- Significantly fewer emissions when run with propane - up to 10x less output
- Digital hour reading – Easily measure running time for maintenance
- Safer design -Engineered and built to mitigate fire risk
- Digital valve controller - Auto shutoff monitoring for fire prevention
- Remote start capability – wiring harness for connecting to controls within the RV for remote starting
- Heat sensor - Built-in protection from overheating and over-revving
- Patent-pending technology – See RVMP Patents for more information
- Exceeds U.S. Forest Services (USFS), CSA, RVIA, and EPA emission requirements.
- Original equipment for Forrest River, NeXus RV, and Thor Industry.
- Backed by our guarantee to provide you the best customer support and a 3-year limited warranty.
- AC/DC Excitation: Brushless PM
- Amps: 33.3
- Design: Multi Pole PM
- Dimensions: 29.5" L x 19.25" W x 13.5" H
- Frequency: 60
- Fuel: Gasoline/LP
- RPM: Variable 2200-3600
- Voltage Regulation: Digital
- Volts: 117-120
- Watts: 4000
- Weight: 121 lb. (54.88 kg)
- Owner's manual
- Installation guide
- Oil funnel
- Spark plug toolkit
- Screwdriver
Electrical Specifications
Alternator Specification
Regulatory Approvals
Mechanical Specifications
Engine Detail
Average Fuel Consumption
Performance @100F/38C and 500 ft./152.4 m altitude
Sound Level @ 10ft. (3M) in dB(A)
Frequently Asked Questions for buying 4000i Dual Fuel Generator
Do you have an Auto Generator Start System?
We will have this ready by the end of 4th quarter 2022. Our generator will work with any auto start feature that has a dry pin connection for starting the generator. The pin out chart within the installation manual will show you which wire to connect your AutoStart system to. We cannot advise as to specific AutoStart systems, as there are too many, but generally speaking this is the process to connect.
Will my existing exhaust system work when doing an install?
Should I operate my generator without an onboard properly functioning carbon monoxide detector?
ABSOLUTELY NOT!!! Failure to adhere to this requirement could result in death.
Should I check all exhaust connections regularly for leaks and tighten them as necessary?
Absolutely exhaust gas is deadly! Do not operate the generator with a faulty exhaust system. Your tailpipe MUST ALWAYS extend beyond the bottom edge of the vehicle sidewall.
I bottomed out on a driveway, what should I do?
Make sure you inspect the unit for damage, paying particular attention to the exhaust pipe that is extending beyond the bottom edge of the vehicle sidewall. If this is damaged be sure to seek service immediately, as this damage could result in inhalation of exhaust gas which is deadly.
Can I store gas, oil, or other flammable materials in the generator compartment?
NO! Do not store anything inside the generator enclosure. This area must always be kept free from debris.
Can I service the generator while it is running?
NO! You must perform on maintenance and service while the generator is off, and the negative battery cable is disconnected. Moving parts can cause injury and or death, and live wires could cause fatal electrocution.
Can I use my RV generator as back-up power in my home or business?
No! Backfeed to utility systems can cause serious risks to life or property. Never connect the generator to an external electrical system except through an approved transfer switch.
Can I use an exhaust extension kit on my generator?
RVMP advises against and does not like to endorse any kits for the following reasons and will impact the FLEX POWER™ Limited Warranty:
Can I buy spare parts for my generator?
Yes, all of the following name brand parts are available for Flex Power generators:
Should I turn off the air conditioners and large electrical loads in my vehicle before starting the generator?
Yes, this is good practice and will keep your generator running optimally.
Should I really follow the breaking procedures?
Yes, following these guidelines in the RVMP Owner’s Manual, will decrease oil consumption and improve long-term power characteristics. The braking process usually involves running the generator at about 50% load for two hours, then 75% load for two hours, then letting it cool down and starting over again. This process is good practice and will pay dividends for the reliability of your generator.
Do I really have to "exercise" my generator?
Yes, it is recommended to run your generator a minimum of 50% capacity for two hours once every month. This prevents the fuel from coming up with varnish, fuel varnishing results in hard starting and surging. Monthly exercising of your unit will keep your generator running well.
What is an AMP?
An amp is the amount of current flowing in a wire or a conductor. Typically RVs have two different categories of amperage: 30 amp or 50 amp. Make sure you know the difference.
What is a volt?
A volt is the amount of electrical potential present, specifically for an RV this is 120 VAC when running on “shore power” (your generator is plugged into the power grid) or when running on generator power. When operating solely on batteries the voltage is 12 VDC.
What is a watt?
Wattage is the representation of power. You calculate wattage by multiplying voltage x amps: 120 VAC x 30 AMPS = 3,600 WATTS. If you look at each item running in your vehicle you can calculate the wattage required versus your wattage available to compare demand on system and capacities.
30 AMP versus 50 AMP
Today all RVs are wired for either 30 or 50 AMP shore power. A 30 AMP electrical cable cored is rated at 120 VAC, and the 50 AMP is rated at 240 VAC. A quick analysis shows a 50 AMP shore cord has close to three times the power potential than a 30 AMP system.
What are the biggest loads in my RV on the generator?
The largest single demand on any generator will be powering the cooling systems. This could be one, two, or even three roof mounted air conditioners. Also, the battery charger demands significant power output from your generator. Understanding and managing these loads is very important to optimizing generator performance.
What are some common loads on the generator in an RV:
Common loads on the generator in an RV:
What is an air conditioner "short-cycling"?
When an air conditioner is running normally pressure is created in the refrigerant. When shut off the system requires at least five minutes for the pressure to equalize. If the air conditioner is started before the pressure equalizes this is called “short-cycling.” This can cause the AC to trip the circuit breaker, overload the generator, and make the AC shut off due to thermal overload. The only way to address this is to allow sufficient time for the AC to equalize pressure and temperature. To prevent this make sure the AC is not blowing directly on the thermostat.
What is worse high altitude or high temperature on generator performace?
Both can cause the generator to lose power and performance. Altitude results in a power decrease of approximately 3% for every 1,000 feet above 500 feet. Temperature results in a 1% loss of operations for each 10℉ above 80℉. In some cases, it may be required to manually adjust the carburetor to overcome some of these performance issues. Please see the Owner’s Manual.
Is it the integrated inverter that allows you to power more sensitive electronics, such as laptops and gaming consoles?
Yes, this allows for variable speed and a more controlled and pure electricity output.
On the digital hour reading, what does that monitor? Frequency? Voltage? Run time? And is there a common name for it or just “digital hour reading”?
Hours of operation, voltage, and various codes. ex P25 oil change at 25 hours. P50 Clean air filter @ 50 hours, P100 replace the fuel and air filters and change engine oil.
What component allows it to run quieter?
The overall assembly. The engine is 30% smaller than Onan with improved output.
Will the low oil indicator flash/illuminate before to alert you of low oil? Or will it automatically shut the engine off if the oil level is too low for safe use and then flash/illuminate?
Yes. It will shut down and/or prevent the unit from starting.
Is this an accurate description for the overload indicator?
In the event your generator is becoming overloaded, the indicator light will begin to flash. If the generator is overloaded and shuts down, simply unplug one or more devices, and push the “restart” button to power the generator back up. Yes. Under normal operating conditions 90F and below 2000 feet above sea level based on user’s current configuration.
What does the output ready indicator entail?
The unit is ready to output power and the unit is operating normally.
What allows it to emit few emissions? What is green machine?
Smaller engine and improved efficiency.
Could you explain what the digital valve controller does?
This is a proprietary feature that allows for seamless operations between propane and gasoline. It also allows for the implementation of a safety feature that allows for the shutdown of fuel in the event of a fire. (Onan does not have this feature.)
Upgrading from an Cummin Onan’s Generator